BPH Surgery Probe / Bipolar Coblation Wand for Detrusor Hypertrophy Treatment Indications: Detrusor Hypertrophy Treatment PLA series products inspection items: Biocompatibility: cytotoxicity EN ISO 10993-5:2009 Test of packaging materials EN ISO 11607-1:2009 Safety regulations Third Edition EN 60601... Mehr sehen
➤ Besuch Webseite
Einzelne Chirurgie-Sonde des Schleifen-Plasma-BPH, Stabs-genaue Entfernung Arthrocare Coblation
Preis: Negotiable
MOQ: 10PCS
Lieferzeit: 1-3 weeks
Marke: MECHAN
Markieren:arthrocare coblation wand, radio frequency probe
Plasma BPH Surgery Probe Precise Ablation Importand Information-Please read Before Use The safe and effective use of plasma surgery system depends to a large degree on factors solely under the control of the operator. There is no substitute for a properly trained and vigilant medical staff. It is im... Mehr sehen
➤ Besuch Webseite
Einzelne Chirurgie-Plasma-Sonde des Schleifen-Entwurfs-BPH mit dünnem Ring und starkem Ring
Preis: Negotiable
MOQ: 10PCS
Lieferzeit: 1-3 weeks
Marke: MECHAN
Markieren:arthrocare coblation wand, radio frequency probe
Single Loop Design BPH Surgery Probe Plasma With Thin Ring And Thick Ring Importand Information-Please read Before Use The safe and effective use of plasma surgery system depends to a large degree on factors solely under the control of the operator. There is no substitute for a properly trained and ... Mehr sehen
➤ Besuch Webseite
Chirurgie-Sonde des Plasma-BPH
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation wand, radio frequency probe
RF Plasma BPH Surgery Probe For Treatment of Urethral Stricture Preoperative preparation 1. Definitive diagnosis; 2. Confirm that the patient has no operation contraindication. For example: Serious cardio cerebral vascular disease, emphysema with pulmonary infection,general hemorrhagic disease, seri... Mehr sehen
➤ Besuch Webseite
Chirurgie-Sonde der niedrigen Temperatur-BPH
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation wand, radio frequency probe
Low Temperature Plasma BPH Surgery Probe For Urethral Stricture Indications: Treat Urethral Stricture Surgery Technical Parameters: Probe shape Column-like Length 283MM Diameter 1.2MM Features: The PLA207 electrode is the gold standard design, used for the treatment of urethral stricture, continuous... Mehr sehen
➤ Besuch Webseite
Zweipoliges BPH-Chirurgie-Sonden-Plasma-kinetischer Ausschnitt mit dem CER/ISO geführt
Preis: Negotiable
MOQ: 10PCS
Lieferzeit: 1-3 weeks
Marke: MECHAN
Markieren:arthrocare coblation wand, radio frequency probe
Bipolar BPH Surgery Probe Plasma Kinetic Cutting Importand Information-Please read Before Use The safe and effective use of plasma surgery system depends to a large degree on factors solely under the control of the operator. There is no substitute for a properly trained and vigilant medical staff. I... Mehr sehen
➤ Besuch Webseite
Chirurgie-Sonde des Edelstahl-zweipolige Plasma-BPH für Prostatectomy
Preis: USD Negotiation
MOQ: Negotiation
Lieferzeit: 5-8 work days
Marke: MECHAN
Markieren:Bipolar Plasma BPH Surgery Probe, Stainless Steel BPH Surgery Probe, prostatectomy radiofrequency ablation probe
Bipolar Plasma BPH Surgery Probe/Loop for Precise Prostatectomy, Bladder Tumor Product Description PLA201 is a bipolar plasma probe which works with PLA-600 Urology Plasma Surgery System, for the treatment of TURP, BPH, Bladder tumor, etc. Prostate Resection is a very conventional surgery, but mostl... Mehr sehen
➤ Besuch Webseite
Zweipoliger Plasma-Plasma-Chirurgie-Sonde zweipoliger Turp-WegwerfStabs-niedrige Temperatur
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Bipolar Plasma Plasma Surgery System BPH Surgery Probe Bipolar TURP Wand Product Introduction PLA201 is a bipolar plasma probe which is using with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostasis and coag... Mehr sehen
➤ Besuch Webseite
Zweipoliger Chirurgie-Sonden-Plasma-Prostataenucleation der Plasma-Chirurgie-BPH klein
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Bipolar Plasma Surgery BPH Surgery Probe Plasma Prostate Enucleation Product Introduction PLA201 is a bipolar plasma probe which is using with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostasis and coagulat... Mehr sehen
➤ Besuch Webseite
PLA201 Procise Plasma-Elektroden-Prostata der Plasma-Stabs-Hochfrequenz-Sonden-BPH
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Procise Plasma Wand BPH Surgery Probe BPH Plasma Electrode Prostate Product Introduction PLA201 is "Gold standard" single ring design, connect with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostas... Mehr sehen
➤ Besuch Webseite
Des langen Lebens-BPH Wellen-Länge Chirurgie-Sonden-Plasma-Prostatades enucleations-286mm
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Procise Plasma Wand BPH Surgery Probe Plasma Prostate Enucleation Product Introduction PLA201 is a bipolar plasma probe which is using with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostasis and coagulation... Mehr sehen
➤ Besuch Webseite
Chirurgie-Sonden-kinetisches Plasma zweipoliges TURP des Procise-Plasma-Stabs-BPH
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Product Introduction PLA201 is "Gold standard" single ring design, connect with PLA-600 Urology Plasma Surgery System, into the treatment of TURP, BPH, Bladder tumor etc.. It has the function of cutting, ablation, hemostasis and coagulation. Product Tip Picture Product Character Really exf... Mehr sehen
➤ Besuch Webseite
Minimal - Invasionsplasma-Chirurgie-Hochfrequenz-Sonde zweipoliges TURP
Preis: Negotiation
MOQ: Negotiation
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Minimally Invasive Plasma Surgery System BPH Surgery Probe Bipolar TURP Product Introduction This PLA201 is using together with PLA-600 Urology Plasma Surgery System, applying to BPH, Prostate surgery disease tissue cutting, ablation, hemostasis and coagulation. Product Diagram Product Character Rea... Mehr sehen
➤ Besuch Webseite
Blasen-Tumor-medizinische und chirurgische Instrument-Plasma-Entfernungs-Stab
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
BPH Surgery Probe / Plasma Ablation Wand / urology Electrode for Bladder Tumor Indications: BPH (Benign Prostate Hyperplasia) Parameters: Total Length 289±2 Cable integrated Yes Saline tube No Features: The PLA201 electrode is the gold standard single loop design, used for resection and coagulation.... Mehr sehen
➤ Besuch Webseite
Sichere BPH-Chirurgie-Sonde, Urologie-Chirurgie-zweipoliges Hochfrequenz-Plasma
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
BPH Surgery Probe / Bipolar Radiofrequency Plasma Wand for Urology Surgery Indications: BPH (Benign Prostate Hyperplasia), Bladder tumor PLA series products inspection items: Biocompatibility: cytotoxicity EN ISO 10993-5:2009 Test of packaging materials EN ISO 11607-1:2009 Safety regulations Third E... Mehr sehen
➤ Besuch Webseite
6.6*1.6mm niedriger Temperaturfühler-Plasma-Stab für Prostatahypertrophie-Chirurgie
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:chirurgische Sonde, arthrocare coblation Stab
Surgery Probe / Low-temperature Plasma Wand for Prostate Hypertrophy Surgery Indications: BPH (Benign Prostate Hyperplasia), Bladder tumor Technical Parameters: Total Length 286mm Probe size 6.6*1.6mm Plug pin 18 Cable integrated Yes Saline tube No Product description: Gold standard single loop desi... Mehr sehen
➤ Besuch Webseite
Einfache Chirurgie-Sonde der Operations-BPH mit genauem zweipoligem und multi polarem Entwurf
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:chirurgische Sonde, Hochfrequenz-Sonde
BPH Surgery Probe / Plasma Kinetic Resection Wand for Bladder Tumor Surgery Indications: BPH (Benign Prostate Hyperplasia), Bladder tumor Technical Parameters: Probe shape Button-like Cable integrated Yes Saline tube No Features: The PLA204 electrode is the gold standard design, used for resection a... Mehr sehen
➤ Besuch Webseite
Chirurgie-Sonde niedrige Temperatur Rfs BPH für eingeschränkte Urin-Fluss-Chirurgie
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:chirurgische Sonde, Hochfrequenz-Sonde
Low-temperature RF Plasma Surgical Wand for Restricted Urine Flow Surgery Indications: Restricted Urine Flow Surgery Technical Parameters: Probe shape Column-like Cable integrated Yes Saline tube No Features: The PLA201 electrode is the gold standard design, used for resection and coagulation of res... Mehr sehen
➤ Besuch Webseite
Kinetische Resektions-Sonden-chirurgisches Instrument, Hochfrequenz-Entfernungs-Sonden-Sofortwiederherstellung
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:chirurgische Sonde, Hochfrequenz-Sonde
Minimally-invasive Plasma Kinetic Resection Wand for Gynecology Surgery Indications: Gynecology Surgery PLA series products inspection items: Biocompatibility: cytotoxicity EN ISO 10993-5:2009 Test of packaging materials EN ISO 11607-1:2009 Safety regulations Third Edition EN 60601-1:2006/AC:2012 Ob... Mehr sehen
➤ Besuch Webseite
Nicht thermisches BPH-Chirurgie-Sonden-Plasma-chirurgischer Stab für Prostatahypertrophie-Chirurgie
Preis: USD piece
MOQ: 5
Lieferzeit: Negotiable
Marke: MECHAN
Markieren:arthrocare coblation Stab, Hochfrequenz-Sonde
Non-thermal Plasma Surgical Wand for Prostate Hypertrophy Surgery Indications: BPH (Benign Prostate Hyperplasia), Bladder tumor Technical Parameters: Total Length 286mm Probe size 6.6*1.6mm Plug pin 18 Cable integrated Yes Saline tube No Product description: Gold standard single loop design, includi... Mehr sehen
➤ Besuch Webseite